Congenital: Fontan
5 Results
- Congenital: Fontan
Progression in Fontan conduit stenosis and hemodynamic impact during childhood and adolescence
The Journal of Thoracic and Cardiovascular SurgeryVol. 162Issue 2p372–380.e2Published online: October 28, 2020- Neil D. Patel
- Connie Friedman
- Cynthia Herrington
- John C. Wood
- Andrew L. Cheng
Cited in Scopus: 8To characterize changes in Fontan conduit size over time and determine if cross-sectional area (CSA) affects cardiac output, pulmonary artery growth, and exercise capacity. - Congenital: FontanOpen Archive
Role of surgeon intuition and computer-aided design in Fontan optimization: A computational fluid dynamics simulation study
The Journal of Thoracic and Cardiovascular SurgeryVol. 160Issue 1p203–212.e2Published online: January 8, 2020- Yue-Hin Loke
- Byeol Kim
- Paige Mass
- Justin D. Opfermann
- Narutoshi Hibino
- Axel Krieger
- and others
Cited in Scopus: 14Customized Fontan designs, generated by computer-aided design (CAD) and optimized by computational fluid dynamics simulations, can lead to novel, patient-specific Fontan conduits unconstrained by off-the-shelf grafts. The relative contributions of both surgical expertise and CAD to Fontan optimization have not been addressed. In this study, we assessed hemodynamic performance of Fontans designed by both surgeon's unconstrained modeling (SUM) and by CAD. - Congenital: Fontan: Basic ScienceOpen Archive
In vivo implantation of 3-dimensional printed customized branched tissue engineered vascular graft in a porcine model
The Journal of Thoracic and Cardiovascular SurgeryVol. 159Issue 5p1971–1981.e1Published online: October 9, 2019- Enoch Yeung
- Takahiro Inoue
- Hiroshi Matsushita
- Justin Opfermann
- Paige Mass
- Seda Aslan
- and others
Cited in Scopus: 19The customized vascular graft offers the potential to simplify the surgical procedure, optimize physiological function, and reduce morbidity and mortality. This experiment evaluated the feasibility of a flow dynamic–optimized branched tissue engineered vascular graft (TEVG) customized based on medical imaging and manufactured by 3-dimensional (3D) printing for a porcine model. - Congenital: FontanOpen Archive
Y-graft modification to the Fontan procedure: Increasingly balanced flow over time
The Journal of Thoracic and Cardiovascular SurgeryVol. 159Issue 2p652–661Published online: July 10, 2019- Phillip M. Trusty
- Zhenglun Wei
- Megan Sales
- Kirk R. Kanter
- Mark A. Fogel
- Ajit P. Yoganathan
- and others
Cited in Scopus: 15The use of Y-grafts for Fontan completion is hypothesized to offer more balanced hepatic flow distribution (HFD) and decreased energy losses. The purpose of this study was to evaluate the hemodynamic performance of Y-grafts over time using serial cardiac magnetic resonance data and to compare their performance with extracardiac Fontan connections. - Congenital: FontanOpen Archive
An in vitro analysis of the PediMag and CentriMag for right-sided failing Fontan support
The Journal of Thoracic and Cardiovascular SurgeryVol. 158Issue 5p1413–1421Published online: April 26, 2019- Phillip M. Trusty
- Mike Tree
- Kevin Maher
- Timothy C. Slesnick
- Kirk R. Kanter
- Ajit P. Yoganathan
- and others
Cited in Scopus: 12Right-sided mechanical circulatory support for failing Fontan physiology has been largely unsuccessful due to inherent hemodynamic differences between these patients and the target populations for most assist devices. This study uses advanced benchtop modeling of Fontan physiology to examine the use of PediMag and CentriMag to improve failing Fontan hemodynamics.