Ronald K. Woods, MD, PhD
Central Message
An assessment of the potential utility of tissue-engineered vascular grafts requires longer-term follow-up.
See Article page 1971.
I congratulate Yeung and colleagues
1
for their development of an elegant, sophisticated, and innovative technology and also commend their collaboration across multiple disciplines and institutions. The basic concept they promote is intuitively very appealing—use patient-specific anatomy, guided by computational fluid dynamics, to develop 3-dimensional (3D) vascular grafts tailored to a given patient's specific needs—in this particular case, the creation of bifurcated pulmonary artery grafts. The reader should look beyond the fact that both animals originally had normal anatomy, as I presume the computer-aided design phase would permit creation of any desired anatomy (for missing parts), which could then be modified to fit the patient's true anatomy. Computational fluid dynamics would then refine the model for function and subsequent 3D printing, mandrel formation, and electrospinning to create the graft.The combination of 3D printing and electrospinning represents a newer generation of decades of effort in the field of tissue engineering and has incredible implications for replacing diseased or missing parts of anatomy. However, an enormity of variables complicate engineering blood vessels.
2
Of the few reports in humans using tissue-engineered grafts predominantly for the Fontan procedure, Sugiura and others3
, 4
, 5
have reported the longest-term follow-up. At 11 years, 28% of patients had undergone angioplasty for graft stenosis.3
The only other in-human application has been for arteriovenous fistulae for dialysis access with 1-year primary patency rates of approximately 30%.6
A recent study in immunodeficient mice offers some sobering, instructive insight.7
The authors compared 3-mm length grafts placed in the intra-abdominal aorta and inferior vena cava and examined them throughout the period required for resorption of the polymer. Grafts in the inferior vena cava performed very well, whereas all grafts in the intra-abdominal aorta failed due to aneurysm formation and rupture. In their review of the literature, the authors comment that there has yet to be a report of an electrospun graft fully degrading and remodeling into a functional neovessel in vivo.With regard to the present report and an anticipated resorption period of 6 months for the polymer, 2 animals and 1 month of follow-up prove nothing other than demonstration of concept. In fact, the notable increase in compliance at 1 month may presage vulnerability to aneurysm formation in a pulsatile vascular bed with systolic pressure considerably greater than what exists in the Fontan circulation. Even a suggestion of durable and safe function will require a larger animal study with much longer follow-up—not an easy task. For now, we can offer encouragement and be grateful that talented individuals such as these authors are developing and testing innovative technology to help congenital heart surgery patients.
References
- In vivo implantation of 3D printed customized branched tissue engineered vascular graft in porcine model.J Thorac Cardiovasc Surg. 2020; 159: 1971-1981.e1
- Tissue engineered vascular grafts: origins, development, and current strategies for clinical application.Methods. 2016; 99: 13-19
- Tissue engineered grafts in children with congenital heart disease: intermediate term follow-up.Semin Thorac Cardiovasc Surg. 2018; 30: 175-179
- Total cavopulmonary connection with new bioabsorbable vascular graft: first clinical experience.J Thorac Cardiovasc Surg. 2017; 153: 1542-1550
- Midterm clinical result of tissue-engineered vascular autografts seeded with autologous bone marrow cells.J Thorac Cardiovasc Surg. 2005; 129: 1330-1338
- Bioengineered human acellular vessels recellurize and evolve into living blood vessels after human implantation.Sci Transl Med. 2019; 11: 1-11
- Differential outcomes of venous and arterial tissue engineered vascular grafts highlight the importance of coupling long-term implantation studies with computational modeling.Acta Biomater. 2019; 94: 183-194
Article info
Publication history
Published online: October 03, 2019
Accepted:
September 18,
2019
Received in revised form:
September 17,
2019
Received:
September 17,
2019
Footnotes
Disclosures: Dr Woods is co-founder of OperVu, Inc, which has no relationship to the content of this work.
Identification
Copyright
© 2019 by The American Association for Thoracic Surgery
User license
Elsevier user license | How you can reuse
Elsevier's open access license policy

Elsevier user license
Permitted
For non-commercial purposes:
- Read, print & download
- Text & data mine
- Translate the article
Not Permitted
- Reuse portions or extracts from the article in other works
- Redistribute or republish the final article
- Sell or re-use for commercial purposes
Elsevier's open access license policy
ScienceDirect
Access this article on ScienceDirectLinked Article
- In vivo implantation of 3-dimensional printed customized branched tissue engineered vascular graft in a porcine modelThe Journal of Thoracic and Cardiovascular SurgeryVol. 159Issue 5
- PreviewThe customized vascular graft offers the potential to simplify the surgical procedure, optimize physiological function, and reduce morbidity and mortality. This experiment evaluated the feasibility of a flow dynamic–optimized branched tissue engineered vascular graft (TEVG) customized based on medical imaging and manufactured by 3-dimensional (3D) printing for a porcine model.
- Full-Text
- Preview